期刊文献+

DSA/NaCl体系电解析出的氯气泡及其影响因素 被引量:5

ELECTROLYTIC EVOLUTION OF CHLORINE BUBBLES FROM DSA/NaCl SYSTEM
在线阅读 下载PDF
导出
摘要 采用激光衍射法研究了DSA/NaCl体系电解析出的氯气泡大小及其分布特点.发现在50~300mA/cm^2区间内电流密度提高,氯气泡增大;电极的取向和结构是影响气泡大小的重要因素;NaCl浓度减小时气泡减小.研究表明,对于多气泡体系,气泡的聚并与电解气泡的大小及分布有密切关系. The chlorine bubble size and distribution electrolytically evolved from DSA/NaCl system were investigated by means of Laser diffraction method. An increase of bubble diameter with increasing current density was observed in the range of 50-300mA/cm2. Electrode orientation and geometry both affected bubble size. When brine concentration was decreased, chlorine bubble diameter became smaller. The results showed that for multi-bubbles system, bubble coalescence might largely determined the bubble size and its distribution.
出处 《化工学报》 EI CAS CSCD 北大核心 1992年第5期556-561,共6页 CIESC Journal
基金 国家自然科学基金资助项目
关键词 电解 气体析出 气泡 electrolytic gas evolution, chlorine bubble size, lasser diffraction method