摘要
详细论述了查找国产660MW超临界机组一次风机振动大的故障原因并进行故障原因分析,通过对一次风机解体检修,从中发现故障并提出解决方案,供业内同行交流参考。
This paper expounds the cause analysis of the abnormal vibration of the primary air fan of the domestic 660MW supercritical unit.Based on the disassembly overhaul of the primary air fan,the causes of the fault have been discovered.Furthermore,relevant solutions can provide reference for similar cases.
作者
张建彪
ZHANG Jianbiao(Ningxia Jingneng Ningdong Power Generation Co.,Ltd.,Yinchuan Ningxia 750400,P.R.China)
出处
《重庆电力高等专科学校学报》
2021年第2期20-23,共4页
Journal of Chongqing Electric Power College