摘要 本文设计了一种基于脱氧核酶(DNAzyme)检测Pb2+的电致化学发光(Electrocheluminescent,ECL)传感器。将对Pb2+特异性识别的DNAzyme通过金-巯键固定于金电极表面,并与标记有二氧化硅包埋的钌联吡啶(Ru-SNPs)的底物DNA链发生杂交,形成双链DNA(ds-DNA)传感器。Pb2+不存在时,由于Ru-SNPs靠近电极表面,产生强的ECL信号。当Pb2+存在时,DNAzyme催化底物链断裂,Ru-SNPs远离电极表面,导致ECL信号下降。实验结果表明ECL强度与Pb2+浓度在0.2-1.0 nmol/L范围内呈良好的线性关系,检测限可达0.04 nmol/L,其他二价金属离子对其基本无干扰。 Here we design an electrochemiluminescent (ECL) DNAzyme-based sensor for detection Pb2+. In this sensor, DNAzyme is immobilized on the gold electrode via Au-thiol interaction, and then hybridizes with DNAzyme substrate labeled with tris ( 2,2' - bipyridyl) ruthenium (II) - doped silica nanoparticles ( Ru- SNPs), forming double- stranded DN A (ds-DNA) sensor. In the absence of Pb2+ Ru-SNPs approach the electrode, which can generate a strong ECL signal. While in the presence of Pb2+ DNAzyme can catalyzes the hydrolytic cleavage of the ds-DNA, and then remove Ru-SNPs away from the electrode, resulting in the reduction of ECL intensity. The result shows that the ECL intensity decreases linearly with Pb2+ concentration in the rang of 0.2-1.0 nmol/L and the detection limit for Pb2+ is 0.04 nmol/L. In addition, the ECL response to other divalent metal ions is negligible.
作者 杨宏芳
出处 《福建分析测试》 CAS 2014年第1期17-21,26,共6页 Fujian Analysis & Testing
关键词 脱氧核酶 传感器 铅离子 电致化学发光 DNAzyme Sensor Pb2+ ECL
  • 相关文献

参考文献15

  • 1Schwartz J. Societal benefits of reducing lead exposure[J].Environmental Research,1994,(01):105-124.
  • 2Winder C,Carmichael N G,Lewis P D. Effects of chronic low level lead exposure on brain development and function[J].TRENDS IN NEUROSCIENCES,1982.207-209.
  • 3Breaker R R,Joyce G F. A DNA enzyme that cleaves RNA[J].CHEMISTRY & BIOLOGY,1994,(04):223-229.
  • 4Wang Z,Lee J H,Lu Y. Label-Free Colorimetric Detection of Lead Ions with a Nanomolar Detection Limit and Tunable Dynamic Range by using Gold Nanoparticles and DNAzyme[J].Advanced Materials,2008,(17):3263-3267.
  • 5Liu J,Lu Y A. DNAzyme catalytic beacon sensor for paramagnetic Cu2+ ions in aqueous solution with high sensitivity and selectivity[J].Journal of the American Chemical Society,2007,(32):9838-9839.
  • 6Hollenstein M,Hipolito C,Lam C. A highly selective DNAzyme sensor for mercuric ions[J].Angewandte Chemie International Edition,2008,(23):4346-4350.
  • 7Wernette D P,Swearingen C B,Cropek D M. Incorporation of a DNAzyme into Au-coated nanocapillary array membranes with an internal standard for Pb (II) sensing[J].The Analyst,2006,(01):41-47.
  • 8Xiao Y,Rowe A A,Plaxco K W. Electrochemical detection of parts-per-billion lead via an electrode-bound DNAzyme assembly[J].Journal of the American Chemical Society,2007,(02):262-263.
  • 9Zhu X,Lin Z,Chen L. A sensitive and specific electrochemiluminescent sensor for lead based on DNAzyme[J].Chemical Communications,2009,(40):6050-6052.
  • 10Zhu X,Zhang Y,Yang W. Highly sensitive electrochemiluminescent biosensor for adenosine based on structure-switching of aptamer[J].Analytica Chimica Acta,2011,(01):121-125.