期刊文献+

电厂专用缓蚀阻垢剂TH-604的性能研究及应用

Research on Performance and Application of Scale and Corrosion Inhibitor TH-604 for Power Plants
在线阅读 下载PDF
导出
摘要 针对分布区域广泛、数目庞大的电厂循环冷却水系统的腐蚀和结垢问题,研制了电厂专用缓蚀阻垢剂TH-604,并实现了工业化生产、销售和应用。TH-604由有机膦酸、聚羧酸、碳钢缓蚀剂及铜缓蚀剂等药剂组成。分别进行了碳酸钙、硫酸钙阻垢试验、缓蚀性能试验。结果显示:参照标准GB/T 16632-2008,同一浓度下,TH-604的碳酸钙阻垢率均高于ATMP、HEDP、PAA和HPMA。参照标准Q/SY 126-2007,其硫酸钙阻垢率为91.8%,符合标准要求。此外,TH-604对电厂循环冷却水系统的碳钢、铜材质具有良好的缓蚀效果,其腐蚀速率分别为0.037 9、0.002 0 mm/a,均符合GB50050-2007要求。并在东北地区一电厂应用6个月,应用结果说明TH-604能使补充水浓缩3倍以上,系统正常运行不结垢,符合GB50050-2007要求。从应用方面证明了TH-604对电厂循环水系统具有良好的缓蚀和阻垢效果。 Aiming at the scale and corrosion problem of circulating cooling water system in power plants, a new type scale and corrosion inhibitor TH-604 was developed, which has been industrially produced and applied. TH-604 is composed of organophosphonic acid, poly-carboxylie acid, carbon iron and copper corrosion inhibitor. The performance of TH-604 was evaluated by using the means of calcium carbonate, calcium sulfate scale inhibition test and rotary coupon corrosion test. The results show that the calcium carbonate scale inhibition rate of TH-604 is higher than ATMP, HEDP, PAA and HPMA according tO the standard GB/T 16632-2008. Calcium sulfate scale inhibition rate is 91.8%, which can meet the requirement of Q/SY 126-2007. The corrosion rate for carbon steel and copper are 0.037 9 and 0.002 0 mm/a as TH-604 is used in circulating cooling water, which can also meet the standard requirement of GB50050-2007. TH-604 has been applied into circulating cooling water of one power plant for six months. It's proved that TH-604 has good inhibition corrosion and scale performance. The feeding water can be concentrated to more than 3 times and the scaling doesn't emerge as TH-604 is used in circulating cooling water, which can meet the standard requirement of GB50050-2007.
出处 《当代化工》 CAS 2012年第12期1309-1311,1314,共4页 Contemporary Chemical Industry
关键词 电厂专用 缓蚀阻垢剂TH-604 性能 应用 Power plant Th-604 scale and corrosion inhibitor Performance Application
  • 相关文献

参考文献7

  • 1于良春,林峰.中国发电能源结构与电力生产可持续性分析[J].山东社会科学,2006(1):92-95. 被引量:12
  • 2辛华人民共和国建设部.GB50050-2007《工业循环冷却水处理设计规范》[S】.北京:中闼计划出版社出版,2008.
  • 3中华人民共和国国家质量监督检验检疫总局/中国困家标准化委员会.GB/T16632-2008《水处理剂阻垢性能的测定》[S].北京:中国标准出版社出版,2008:1-3.
  • 4中国石油天然气集团公司.Q/SYt26-2007《油田水处理用缓蚀阻垢剂技术要求》[S].北京:石油工业出版社,2000.1-6.
  • 5国家质量技术监督局.GB/T18175-2000《水处理剂缓蚀性能的测定-旋转挂片法》【S].北京,2000:7-12.
  • 6国家电力公司热工研究院.DL/T806-2002《火力发电厂循环冷却水用阻垢缓蚀剂》[S].陕西,2002:1-6.
  • 7王兵,李长俊,廖柯熹,徐庆磊,刘颖,彭波.管道结垢原因分析及常用除垢方法[J].油气储运,2008,27(2):59-61. 被引量:92