摘要 制备了Cu-Mg-Al三元类水滑石修饰玻碳电极,研究了亚硝酸根在修饰电极上的电化学行为,Cu-Mg-Al三元类水滑石对亚硝酸根的电化学氧化具有明显的催化活性,评估了溶液pH值、扫描速率和施加电位对亚硝酸盐电流响应的影响,计算了电机有效表面积和NO2-在修饰电极表面的吸附容量,并初步探讨了催化机理,在优化的实验条件下,该修饰电极对NO2-的测定线性范围为0.1~10.42μmol/L,检测限为0.08μmol/L(S/N=3)。将该传感器用于食品中亚硝酸根离子的测定,结果满意。 Cu-Mg-Al ternary hydrotalcite-like compound modified glassy carbon electrode was prepared,and the electrochemical behavior of nitrite on the modified electrode was studied.The modified electrode exhibited obvious catalytic activity for electrochemical oxidation of nitrite.The effect of solution pH,potential scan rate and electric potential on current response was studied,and the effective surface area of the electrode and the adsorption capacity NO^-_2 on the electrode were measured.Under optimized experimental conditions,the linear range for the determination of NO^-_2 was 0.1~10.42 μmol/L,and the detection limit was 0.08 μmol/L(S / N = 3).The sensors gave satisfactory results when used for detection of intrite in food.
出处 《化学世界》 CAS CSCD 北大核心 2010年第11期649-651,645,共4页 Chemical World
关键词 类水滑石 化学修饰电极 亚硝酸根 安培检测 hydrotalcite-like compound chemically modified electrode nitrite amperometric detection
  • 相关文献

参考文献9

  • 1王镇浦,吴宏,陈国松.水中痕量亚硝酸盐氮的反相流动注射一光度测定[J].中国环境科学,1999,19(5):469-471. 被引量:16
  • 2Wang G F,Satake M,Horita K.Talanta[J],1998,46:671-678.
  • 3Gao F,Zhang L,Wang L,et al.Anal Chim Acta[J],2005,533:25-29.
  • 4Ito K,Takayama Y,Makabe N,et al.J of Chromatog A[J],2005,1083:63-67.
  • 5Rives V,Angeles Ulibarri M.Coord Chem Rev[J].1999,181(1):61-120.
  • 6Kannan S,Dubey A,Knozinger H,Catal[J],2005,231;38192.
  • 7Laviron E.J Electroanal Chem[J],1974,52:355-393.
  • 8Anson F.Anal Chem[J],1964,36:932-934.
  • 9Adams R.Electrochemistry at solid electrodes[M].Dekker New York,1969.

二级参考文献6

  • 1国家环境保护局.水和废水监测分析方法(第3版)[M].北京:中国环境科学出版社,1989.354-356.
  • 2Fresenius W 张曼平等(译).水质分析[M].北京:北京大学出版社,1991.135-139.
  • 3张曼平(译),水质分析,1991年,135页
  • 4王镇浦,水质词汇.水质取样和分析方法国际标准(ISO),1989年,208页
  • 5国家环保局,水和废水监测分析方法(第3版),1989年,260页
  • 6GB/T 7493 1987 水质亚硝酸氮的测定一分光光度法,1987年

共引文献15

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部