锅炉性能优化系统在300MW“W”形火焰锅炉上的应用

Application of "System Optimization Analysis Program" in 300 MW boiler with 'W'-shape flame
在线阅读 下载PDF
导出
摘要 通过对锅炉性能优化系统软件在300MW"W"形火焰锅炉上实际应用效果的对比分析,对100%ECR(额定连续出力),90%ECR,83%ECR,75%ECR,53%ECR(调峰最低负荷)等工况进行了锅炉性能优化试验,得出了各负荷段的最佳优化运行曲线。优化结果证明了优化方向的正确性,可为#2、#3、#4锅炉及同类型燃烧方式锅炉的优化运行提供参考和借鉴。 The application effects of the 'System Optimization Analysis Program' in 300MW boiler with 'W'-shape flame were analyzed.Under the conditions of 100%ECR(economical continuous rating),90%ECR,83%ECR,75%ECR and 53%ECR(peak shaving minimum load),the optimization experiments of the boiler performance were carried out,and the optimized operation curves of various loads were obtained.The optimized results shows that the optimization direction is correct;and it can be used as reference for the operation optimization of boilers No.2,No.3,No.4 and other boilers with the same combustion mode.
出处 《华电技术》 CAS 2010年第9期25-29,51,共6页 HUADIAN TECHNOLOGY
关键词 “W”形火焰锅炉 锅炉性能优化 人工智能神经网络 数学模型 应用及分析 boiler with 'W'-shaped flame optimization of boiler performance artificial intelligent neural network mathematical model application and analysis
  • 相关文献

参考文献3

  • 1北京埃普瑞电力科技有限公司.大方发电有限公司 #1锅炉性能优化二期项目竣工报告[R].北京:北京埃普瑞电力科技有限公司,2009.
  • 2王秀林,孔令君,姜仕涛,张竟思,付全方,张世荣,杨启璋.锅炉性能优化系统的应用试验研究[J].电力技术(北京),2004,37(12):45-48. 被引量:14
  • 3周强泰.锅炉原理[M].2版.北京:中国电力出版社,2009.

二级参考文献6

  • 1青岛发电厂1号炉电除尘烟尘浓度检测报告[R].山东电力研究院(烟气类第HB20020004号),2002.
  • 2青岛发电厂2号锅炉燃烧器改造后性能试验报告(编号:9986026)[R].热工研究院热力性能及计量研究所,1999.
  • 3青岛发电厂2号炉NOx排放量试验报告[R].青岛发电厂,2003.
  • 4青岛发电厂2号炉“SOAP”性能优化系统试验报告[R].北京埃普瑞电力科技有限公司,2004.
  • 5毕玉森.电站锅炉 NO_x 排放现状、预测及技术政策[J].中国电力,1998,31(12):59-62. 被引量:36
  • 6吴少华,刘辉,姜秀民,邱朋华,秦裕琨.采用超细煤粉再燃技术 降低氮氧化物排放[J].中国电力,2003,36(2):1-4. 被引量:38