期刊文献+

Fenton试剂处理含甲醛有机废水的研究 被引量:15

Treatment of organic wastewater containing formaldehyde by Fenton reagent
在线阅读 下载PDF
导出
摘要 研究了Fenton试剂处理含甲醛有机废水的影响因素及其适宜条件。试验结果表明各影响因素的适宜条件为:在原水CODCr约为1000 mg/L时,n(H2O2)/n(Fe2+)=4,H2O2的投加量为72mmol/L,pH=3,反应时间为2 h。此时CODCr的去除率可达90.85%。同时,考察了Fenton试剂预处理含甲醛为主的脲醛树脂废水的效果,在适宜条件下CODCr的去除率可达80.56%。 The influencing factors and optimal operating conditions for the treatment of organic waste water containing formaldehyde using Fenton reagent were studied. The optimal operating conditions determined by experiment are as follows: when the CODCr, of the wastewater was about 1 000 mg/L, n(H2 O2 ) : n(Fe^2+) = 4,the dosage of H2O2 was 72 mmol/L,pH = 3 and the oxidation time was 2 hours. Under these conditions, the CODCr, removal rates were up to 90. 85 %. The effect of the pretreatment of urea formaldehyde resin waste water containing formaldehyde using Fenton reagent was also studied. Under the optimal operating conditions,the CODCr, removal rates were up to 80.56%.
出处 《化工科技》 CAS 2007年第3期26-28,共3页 Science & Technology in Chemical Industry
关键词 FENTON试剂 脲醛树脂 甲醛 化学氧化 Fenton reagent Urea formaldehyde resin Formaldehyde Chemical oxidation
  • 相关文献

参考文献4

二级参考文献19

  • 1王怡中,李忠,尹玲,胡克源.有机磷农药废水湿式空气氧化预处理的研究[J].环境化学,1993,12(5):408-414. 被引量:27
  • 2杜鸿章,房廉清,江义,吴荣安,李文钊,尹承龙,计中坚.焦化污水催化湿式氧化净化技术[J].工业水处理,1996,16(6):11-13. 被引量:54
  • 3张秋波 李忠 等.酚水及煤气化废水的湿式氧化处理[J].环境科学学报,1987,7(3):305-311.
  • 4张乃东.HV/Fe(C2O4)^3-3/H2O2法处理苯胺类废水的研究[M].哈尔滨:哈尔滨工业大学,1999..
  • 5魏复盛,水和废水监测分析方法,1989年
  • 6团体著者,1985年
  • 7张秋波.煤加压气化废水的催化湿式氧化处理[J].环境科学学报,1988,8(1):98-105.
  • 8Yu Jianli,Environ Sci Technol,2000年,34卷,15期,3191页
  • 9张乃东,学位论文,1999年
  • 10Zhong Yiding,Ind Eng Chem Res,1996年,35卷,10期,3257页

共引文献117

同被引文献111

引证文献15

二级引证文献72

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部