摘要 报道了用于微波等离子体炬原子发射光谱仪(MPT-AES)的新型注射泵-超声雾化器联用进样系统, 考察了影响该系统性能的因素. 分别用气动雾化进样系统和注射泵-超声雾化联用进样系统进样, 测定了Cd, Cu, Mg, Ca和Na等5种元素、浓度均为1×10-4%的混合溶液. 结果表明, 注射泵-超声雾化联用进样系统所得的谱线强度是气动进样所得谱线强度的2~3倍, 而超声雾化进样的检出限比气动雾化进样小2~10倍, 且超声雾化进样系统的记忆效应较强, 所需清洗时间较长. The feeding-sample system of MPT-AES is pneumatic nebulization system, but its efficiency is not good. A new-built injector pump-ultrasonic nebulizer combination feeding-sample system has been designed. Its performance was tested and compared with that of the pneumatic nebulization system. It can be concluded that the new-built feeding-sample system can increase the spectral line intensity about 23 times and decrease the detection limit about 210 times. Moreover, this new-built system can reduce the time taken by washing the sample cell from 30 min or so to about 10 min.
出处 《吉林大学学报(理学版)》 CAS CSCD 北大核心 2005年第4期502-506,共5页 Journal of Jilin University:Science Edition
关键词 注射泵-超声雾化联用进样 MPT-AES 气动雾化进样 <Keyword>injector pump-ultrasonic nebulizer MPT-AES pneumatic nebulization system
  • 相关文献

参考文献13

  • 1弓振斌,梁枫,金钦汉,黄本立.微波等离子体炬离子/原子荧光光谱研究——稀土元素铕的离子/原子荧光光谱[J].光谱学与光谱分析,1999,19(3):356-359. 被引量:12
  • 2Barnes J H, Gron O A, Hieftje G M. Characterization of an Argon Microwave Plasma Torch Coupled to a Mattauch-herzog Geometry Mass Spectrometer [J]. Journal of Analytical Atomic Spectrometry, 2002, 17: 1132-1136.
  • 3师宇华,郑健,王美佳,于爱民.氩微波等离子体炬作为气相色谱离子化检测器的研究[J].吉林大学学报(理学版),2003,41(3):378-383. 被引量:3
  • 4Liang F, Zhang D, Lei Y, et al. Determination of Selected Noble Metals by MPT-AES Using a Pneumatic Nebulizer [J]. Microchem J, 1995, 52(2): 181-187.
  • 5Jankowski K, Karmasz D, Starski L, et al. Characteristics of Nebulizers for Microwave-induced Plasma Atomic Emission Spectrometry: Ⅰ. Pneumatic Nebulizers [J]. Spectrochimica Acta, 1997, 52B(12): 1801-1812.
  • 6Wendt R H, Fassel V A. Induction-coupled Plasma Spectrometric Excitation Source [J]. Anal Chem, 1965, 37(7): 920-922.
  • 7West C D, Jume D N. Rapidfrequency Plasma Emission Spectrophotometer [J]. Anal Chem, 1964, 36(2): 412-415.
  • 8Goulden P D, Anthony D H J. Modified Ultrasonic Nebulizer for Inductively Coupled Argon Plasma Atomic Emission Spectrometry [J]. Anal Chem, 1984, 56(13): 2327-2329.
  • 9李一木,段忆翔,张寒琦,金钦汉,杜朝晖.超声雾化进样法MPT-AFS的研究[J].分析试验室,1996,15(3):24-27. 被引量:4
  • 10张俊卿,杨文斌,魏继中.超声雾化ICP-AES的研究[J].分析测试学报,1995,14(6):82-85. 被引量:3

二级参考文献13

共引文献16

同被引文献6

引证文献2

二级引证文献18

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部