期刊文献+

用于X射线时空分辨测量的弯晶谱仪 被引量:4

Bent Crystal Spectrometer for X-ray Space and Time Resolved Measurements
在线阅读 下载PDF
导出
摘要 为了测量激光聚变产生的0.2~0.37 nm范围内的等离子体X射线,设计了一种基于空间和时间分辨的聚焦型弯晶谱仪.将在700℃时弯曲后的LiF(2d=0.403 nm)晶体作为色散元件,布喇格衍射角的变化范围为30~67.5°,弯晶粘贴在离心率和焦距分别为0.9586和1350 mm的椭圆形不锈钢基底上.利用弯晶谱仪配X光CCD相机在星光Ⅱ激光(0.35 μm,60~80J,700 ps)装置上摄取了钛平面靶发射的X射线光谱,实验结果表明它的光谱分辨率能达到0.001 nm. In order to measure plasma X-ray produced by laser fusion in the 0.2~0.37 nm range, a focusing bent crystal spectrometer has been designed for measuring the spatial and temporal resolutions. The LiF crystal with a 2d spacing of 0.403 nm was elliptically bent at 700°C for the dispersive element, the Bragg diffractive angles vary from 30 to 67.5 degrees, the bent LiF crystal was fixed on the elliptical stainless-steel substrate with an eccentricity of 0.9586 and a focal distance of 1350 mm. The X-ray spectrum emitted from the planar titanium target was photographed by using the bent crystal spectrometer coupled with the X-ray CCD camera at the XG-2 laser facility, the experimental result shows that the spectral resolution is up to 0.001 nm.
出处 《光子学报》 EI CAS CSCD 北大核心 2005年第5期722-725,共4页 Acta Photonica Sinica
基金 国家863高技术资助项目(863 804 3)
关键词 弯晶谱仪 激光等离子体 X射线光谱 空间分辨率 时间分辨率 Bent crystal spectrometer Laser-produced plasmas X-ray spectrum Spatial resolution Temporal resolution
  • 相关文献

参考文献11

  • 1李三伟,陈波,丁耀南,杨家敏,王耀梅,丁永坤,王红斌,唐道源.铝靶电子温度空间分布实验诊断[J].原子与分子物理学报,1999,16(4):467-470. 被引量:4
  • 2Hermann J, Thomann A L, Boulmer-Leborqne C, et al.Plasma diagnostics in pulsed laser TiN layer deposition. J Appl Phys, 1995,77 (7) : 2928 - 2936.
  • 3Sorge S, Wierting A, Roepke G, et al. Diagnostics of a laser-induced dense plasma by hydrogen-like carbon spectra.J Phys B, 2000, 33(16):2983-3000.
  • 4Rosmej F B, Hoffmann D H H, C, eissel M, et al. Advanced x-ray diagnostics based on an observation of high-energy Rydberg transitions from autoionizing levels in dense laserproduced plasmas. Phys Rev A, 2001,63(6): 1 -8.
  • 5熊先才,钟先信,段绍光,肖沙里,杨国洪,高洁.软X射线分光晶体KAP的反射率特性[J].光子学报,2004,33(1):73-75. 被引量:10
  • 6张继彦,杨国洪,张保汉,周裕清,李军.小型平焦场光栅光谱仪的研制[J].光学学报,2001,21(9):1099-1102. 被引量:15
  • 7范品忠,关铁堂.软X射线晶体谱仪[J].光学学报,1995,15(7):923-926. 被引量:11
  • 8Hammel B A, Ruggles L E. Elliptical spectrograph gated microchannel-plate detector for time resolved spectral measurements in the x-ray region. Rev Sci Instrum, 1988 ,59(8) : 1828 - 1830.
  • 9Nagasawa H. Spherically bent crystal spectrometer for inelastic high-energy x-ray scattering experiments. Rev Sci Instrum, 1989,60(7) : 2051 -2053.
  • 10Koenig M, Boudenne J M, Legriel P, et al. A computer driven crystal spectrometer with charge coupled device detectors for x-ray spectroscopy of laser plasmas. Rev Sci Instrum, 1997,68(6) : 2387 -2392.

二级参考文献14

  • 1范品忠,关铁堂.软X射线晶体谱仪[J].激光与光电子学进展,1995,32(A01):142-142. 被引量:4
  • 2杨家敏,丁耀南,郑志坚,易荣清,王耀梅,唐道源.5F软X光胶片响应特性研究[J].光学学报,1997,17(5):599-603. 被引量:9
  • 3张正泉,光学学报,1987年,7卷,4期,324页
  • 4Young B K F,Phys Rev Lett,1988年,61卷,25期,2851页
  • 5李英骏,博士学位论文,1998年
  • 6Feng X, Liu M H, Lee S A. A transmission grating spectrograph and its application in both laser plasma and plasma focus.Rev Sci Instrum, 1997,68(8):3068-3073
  • 7Henke B L, Lee P, Tanaka T J,et al. Low-energy x-ray interaction coefficients: photoabsorption, scattering, and reflection.Atomic Data and Nuclear Data Tables, 1982,27(1):1-16
  • 8Zhong X X, Xiong X C, Xiao S L,et al. Analysis and calculation on transmission efficiency of two-channel elliptical crystal spectrometer. in:Tan Jiubin,Wen Xianfang eds. Proceedings of 2nd International Symposium on Instrumentation Science and Technology,
  • 9陈志伟,王占山,牛惠辉.软X射线狭缝透射光栅谱仪的研制[J].光学精密工程,2000,8(3):254-257. 被引量:6
  • 10关铁堂.软X射线分光晶体马来酸氢十八酯[J].光学学报,1991,11(4):353-356. 被引量:3

共引文献35

同被引文献56

引证文献4

二级引证文献20

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部